Technical Information
Deltabar M PMD55
Differential pressure measurement
Differential pressure transmitter with metal sensor
Communication via HART, PROFIBUS PA or FOUNDATION
Fieldbus
Application
The Deltabar M differential pressure transmitter is used
for the following measuring tasks:
Flow measurement (volume or mass flow) in
conjunction with primary elements in gases, vapours
and liquids
Level, volume or mass measurement in liquids
Differential pressure monitoring, e.g. of filters and
pumps
Your benefits
Reference accuracy: 0,1%
as PLATINUM version: up to 0,075%
Turn down up to 100:1
Compact transmitter design
Quick commissioning via DIP switches
Easy and safe menu-guided operation
on-site via display module
via 4 to 20 mA with HART
via PROFIBUS PA
via FOUNDATION Fieldbus
Continuous modularity for differential pressure,
hydrostatic and pressure (Deltabar M, Deltapilot M
Cerabar M), e.g.
replaceable display
universal electronics
International usage thanks to a wide range of approvals
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Deltabar M PMD55

TI00434P/00/EN/15.1171128311Technical InformationDeltabar M PMD55Differential pressure measurementDifferential pressure transmitter with metal sensorC

Page 2 - Table of contents

Deltabar M PMD55 10 Endress+HauserDead time, Time constantP01-xxxxxxxx-05-xx-xx-xx-036Presentation of the dead time and the time constantDynamic beha

Page 3 - Function and system design

Deltabar M PMD55Endress+Hauser 11Dynamic behavior: FOUNDATION FieldbusReading cycle• Cyclic: max. 10/s (dependent on the number and type of function b

Page 4 - 4 Endress+Hauser

Deltabar M PMD55 12 Endress+HauserData of the FOUNDATION Fieldbus interfaceBasic dataVirtual communication references (VCRs)Link settingsTransducer B

Page 5 - Endress+Hauser 5

Deltabar M PMD55Endress+Hauser 13Function blocksBlock Content Number of blocksExecution time FunctionalityResource Block The Resource Block contains a

Page 6 - 6 Endress+Hauser

Deltabar M PMD55 14 Endress+HauserPower supplyElectrical connection Note!• When using the measuring device in hazardous areas, installation must comp

Page 7 - Endress+Hauser 7

Deltabar M PMD55Endress+Hauser 15FOUNDATION FieldbusThe digital communication signal is transmitted to the bus via a 2-wire connection. The bus also p

Page 8 - 8 Endress+Hauser

Deltabar M PMD55 16 Endress+HauserDevices with M12 plugPIN assignment for M12 connectorEndress+Hauser offers the following accessories for devices wi

Page 9 - Endress+Hauser 9

Deltabar M PMD55Endress+Hauser 17Supply voltage Note!• When using the measuring device in hazardous areas, installation must comply with the correspon

Page 10 - 10 Endress+Hauser

Deltabar M PMD55 18 Endress+HauserPerformance characteristicsReference operating conditions• As per IEC 60770 and IEC 61298-1, Sections 5 to 7• Ambie

Page 11 - Endress+Hauser 11

Deltabar M PMD55Endress+Hauser 19Influence of the static pressureNote!The influence of the static pressure on the zero point can be calibrated out.Tot

Page 12 - 12 Endress+Hauser

Deltabar M PMD552 Endress+HauserTable of contentsFunction and system design. . . . . . . . . . . . . . . . . . . . . 3Measuring principle . . . . . .

Page 13 - Endress+Hauser 13

Deltabar M PMD55 20 Endress+HauserInfluence of the installation positionThe recommended maximum angle to the axis of the diaphragm is 10° and results

Page 14 - Power supply

Deltabar M PMD55Endress+Hauser 21Operating conditions (Installation)General installation instructions• The position-dependent zero shift can be correc

Page 15 - Endress+Hauser 15

Deltabar M PMD55 22 Endress+HauserWall and pipe-mounting (optional)Endress+Hauser offers a mounting bracket for installing the device on pipes or wal

Page 16 - 16 Endress+Hauser

Deltabar M PMD55Endress+Hauser 23Typical installation arrangementsP01-PMD55xxx-17-xx-xx-xx-001A: Installation for horizontal impulse pipes; H2 version

Page 17 - Endress+Hauser 17

Deltabar M PMD55 24 Endress+HauserOxygen applications Oxygen and other gases can react explosively to oils, grease and plastics, such that, among oth

Page 18 - Performance characteristics

Deltabar M PMD55Endress+Hauser 25Operating conditions (Environment)Ambient temperature range • –40...+85°C (–40 to +185°F)• On-site display: -20 to +7

Page 19 - Endress+Hauser 19

Deltabar M PMD55 26 Endress+HauserOperating conditions (Process)Process temperature limits(temperature at transmitter)• Process connections made of 3

Page 20 - 20 Endress+Hauser

Deltabar M PMD55Endress+Hauser 27Mechanical constructionProcess connection Oval flange, connection 1/4-18 NPT IEC61518P01-PMD55xxx-11-xx-xx-xx-015Desi

Page 21 - Endress+Hauser 21

Deltabar M PMD55 28 Endress+HauserDimensions V1 version; Impulse pipe vertical; alignment 90°P01-PMD55xxx-06-xx-xx-xx-001A: Version cover without win

Page 22 - 22 Endress+Hauser

Deltabar M PMD55Endress+Hauser 29Dimensions H1 version; Impulse pipe horizontal;alignment 180° P01-PMD55xxx-06-xx-xx-xx-002A: Version cover without wi

Page 23 - Endress+Hauser 23

Deltabar M PMD55Endress+Hauser 3Function and system designMeasuring principleP01-PMD55xxx-03-xx-xx-xx-001Measuring cell of the Deltabar M1 Sensing ele

Page 24 - 24 Endress+Hauser

Deltabar M PMD55 30 Endress+HauserDimensions H2 version; Impulse pipe horizontal; alignment 90°P01-PMD55xxx-06-xx-xx-xx-003A: Version cover without w

Page 25 - Endress+Hauser 25

Deltabar M PMD55Endress+Hauser 31Material (not wetted) Housing P01-xMxx3xxx-14-xx-xx-xx-002Front view, right-hand side view, top view.Filling oil• Sil

Page 26 - 26 Endress+Hauser

Deltabar M PMD55 32 Endress+HauserConnecting partsP01-PMD55xxx-06-09-xx-xx-001Material (wetted) Side flangesEndress+Hauser supplies side flanges made

Page 27 - PMD55, H1 PMD55, V1

Deltabar M PMD55Endress+Hauser 33Human interfaceLocal operation Operating keys and elements located on the electronic insertFunction of the DIP switch

Page 28 - 28 Endress+Hauser

Deltabar M PMD55 34 Endress+HauserFunction of the operating keysNote!The operation via the keys on the electronic insert is only possible if the onsi

Page 29 - Endress+Hauser 29

Deltabar M PMD55Endress+Hauser 35Local display (optional)A 4-line liquid crystal display (LCD) is used for display and operation. The local display sh

Page 30 - 30 Endress+Hauser

Deltabar M PMD55 36 Endress+HauserRemote operation All software parameters are accessible depending on the position of the write protection switch o

Page 31 - Endress+Hauser 31

Deltabar M PMD55Endress+Hauser 37Hardware and software for onsite and remote operationCommubox FXA195For intrinsically safe HART communication with Fi

Page 32 - 32 Endress+Hauser

Deltabar M PMD55 38 Endress+HauserCertificates and approvalsCE mark The device meets the legal requirements of the relevant EC directives. Endress+Ha

Page 33 - SW / Alarm min

Deltabar M PMD55Endress+Hauser 39Ordering informationPMD55 This overview does not mark options which are mutually exclusive.010 Approval:AA Non-hazard

Page 34 - 34 Endress+Hauser

Deltabar M PMD55 4 Endress+HauserFlow measurement Design and operation modeP01-PMD55xxx-15-xx-xx-xx-001Flow measurement with Deltabar M PMD55 and pri

Page 35 - Endress+Hauser 35

Deltabar M PMD55 40 Endress+HauserP01-PMD55xxx-11-xx-xx-xx-01288 Prepared for Deltatop080 Reference Accuracy:DPlatinumGStandard090 Calibration; Unit:

Page 36 - 36 Endress+Hauser

Deltabar M PMD55Endress+Hauser 41Additional ordering information (optional)500 Additional Operation Language:AA EnglishAB GermanAC FrenchAD SpanishAE

Page 37 - Endress+Hauser 37

Deltabar M PMD55 42 Endress+HauserAdditional documentationTechnical Information • EMC test procedures TI00241F/00/EN• Cerabar M: TI00436P/00/EN• Delt

Page 38 - Certificates and approvals

Deltabar M PMD55Endress+Hauser 43Installation/Control DrawingsAuthority Version in the order codeApproval Electronics DocumentationFMFAIS Cl.I,II,III

Page 39 - Endress+Hauser 39

Deltabar M PMD55 44 Endress+HauserConfiguration data sheetPressure The following configuration data sheet has to be filled in and to be included in t

Page 40 - 40 Endress+Hauser

Deltabar M PMD55Endress+Hauser 45Level The following configuration data sheet has to be filled in and to be included in the order when the option &quo

Page 41 - Endress+Hauser 41

Deltabar M PMD55 46 Endress+HauserFlow The following configuration data sheet has to be filled in and to be included in the order when the option &qu

Page 42 - Additional documentation

Deltabar M PMD55Endress+Hauser 47

Page 43 - Endress+Hauser 43

Deltabar M PMD55Instruments InternationalEndress+HauserInstruments International AGKaegenstrasse 24153 ReinachSwitzerlandTel. +41 61 715 81 00Fax +41

Page 44 - Measured value (%)

Deltabar M PMD55Endress+Hauser 5Typical arrangements for flow measurementsP01-PMD55xxx-11-xx-xx-xx-011A: liquid in vertical pipe; H1 version; horizont

Page 45 - Endress+Hauser 45

Deltabar M PMD55 6 Endress+HauserCommunication protocol • 4 to 20 mA with HART communication protocol• PROFIBUS PA– The Endress+Hauser devices meet t

Page 46 - (default)

Deltabar M PMD55Endress+Hauser 7InputMeasured variable Differential pressure, from which flow (volume or mass current) and level (level, volume or mas

Page 47 - Endress+Hauser 47

Deltabar M PMD55 8 Endress+HauserExplanation of termsExplanation of the terms: Turn down (TD), set span and zero based span Case 1:• Lower range val

Page 48

Deltabar M PMD55Endress+Hauser 9OutputOutput signal • 4 to 20 mA with superimposed digital communication protocol HART 6.0, 2-wire• Digital communica